STA-LUBE, INC. -- STA-LUBE HYDRAULIC & JACK OIL -- 9150-00N009781 ===================== Product Identification =====================
Product ID:STA-LUBE HYDRAULIC & JACK OIL
MSDS Date:06/01/1987
FSC:9150
NIIN:00N009781
=== Responsible Party ===
Company Name:STA-LUBE, INC.
Address:3039 ANA STREET
City:RANCHO DOMINGUEZ
State:CA
ZIP:90221
Info Phone Num:213 537-5650
Emergency Phone Num:303 893-7774(POISINDEX)
Preparer's Name:NELSON ALLEY
CAGE:FO996
=== Contractor Identification ===
Company Name:STA-LUBE INC
Address:3039 ANA ST
Box:City:RANCHO DOMINGUEZ (PART OF COMPTON)
State:CA
ZIP:90221
Country:US
Phone:310-664-2121/800-424-9300(CHEMTREC)
CAGE:33876
Company Name:STA-LUBE, INC.
Address:3939 ANNA ST
City:RANCHO DOMINGUEZ
State:CA
ZIP:90221
Phone:(213) 537-5650
CAGE:FO996
============= Composition/Information on Ingredients =============
Ingred Name:SOLVENT REFINED NAPHTHENIC AND PARAFFINIC PETROLEUM OILS
CAS#64741-96-4, 66742-18-3
CAS:64741-89-5
RTECS #:PY8041500
Fraction by Wt: 98%
Other REC Limits:5MGM3
OSHA PEL:5MGM3
ACGIH TLV:5MGM3
Ingred Name:PROPRIETARY ZN,P,S ADDITIVE
Fraction by Wt: 1%
Other REC Limits:NA
OSHA PEL:
ACGIH TLV:
===================== Hazards Identification =====================
LD50 LC50 Mixture:
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:AVOID PRODUCTION OF OIL MISTS.
Explanation of Carcinogenicity:N/A FPN
Effects of Overexposure:DERMATITIS IN SENSITIVE PEOPLE. DIZZINESS FROM
OIL FOGS.
Medical Cond Aggravated by Exposure:DERMATITIS.
======================= First Aid Measures =======================
First Aid:INHALE:OIL FOGS REMOVE TO FRESH AIR-CALL PHYSICIAN.
SKIN:DERMATITIS-WASH WITH SOAP AND WATER.USE GLOVES. INGEST:CALL MD
IMMEDIATELY
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:380F/191.4C
Extinguishing Media:FOAM/WATER FOG,DRY CHEMICAL, CO*2,VAPORIZING LIQUID
TYPE EXTINGUISHING AGENTS
Fire Fighting Procedures:STANDARD PETROLEUM PROCEDURES: USE NIOSH/MSHA
APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT
Unusual Fire/Explosion Hazard:
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE WITH ABSORBENT MATERIAL SUCH AS SAND,
CLAY, ETC.REMOVE FROM WATER BY SKIMMING. KEEP OUT OF SEWERS. WASH
WITH SAFETY SOLVENT AND/OR DETERGENT AND WATER.
Neutralizing Agent:
====================== Handling and Storage ======================
Handling and Storage Precautions:PETROLEUM OILS ARE RELATIVELY
NON-VOLATILE PRODUCTS&PRESENT NO VAPOR HAZARDS AT ROOM
TEMPERATURE.AVOID PRODUCTION OF OIL MISTS.
Other Precautions:KEEP CLEAN AND DRY.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE NORMALLY NEEDED. NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN
Ventilation:CONSULT LOCAL SAFETY/HEALTH AUTHORITIES IF ADDITIONAL
GUIDANCE IS NECESSARY
Protective Gloves:FOR SENSITIVE PERSONS.
Eye Protection:AS NECESSARY-NOT NORMALLY NEEDED.
Other Protective Equipment:
Work Hygienic Practices:CUSTOMARY GOOD HYGIENE.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:>500F/257C
Vapor Density:>1
Spec Gravity:0.90
Evaporation Rate & Reference:<1 WATER=1
Solubility in Water:NIL
Appearance and Odor:LIGHT YELLOW, OILY LIQUID; NOT OBJECTIONABLE ODOR.
Percent Volatiles by Volume:NIL
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:
Hazardous Decomposition Products:CO, CO*2, H*2S(TRACE)
Conditions to Avoid Polymerization:
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL,STATE AND
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.