ATLAS POWDER CO -- AMMONIUM NITRATE -- 1375-00N051669
===================== Product Identification =====================
Product ID:AMMONIUM NITRATE
MSDS Date:01/06/1986
FSC:1375
NIIN:00N051669
=== Responsible Party ===
Company Name:ATLAS POWDER CO
Address:15301 DALLAS PARKWAY SUITE 1200
City:DALLAS
State:TX
ZIP:75248
Country:US
Info Phone Num:717-386-4121
Emergency Phone Num:717-386-4121
Preparer's Name:H. BOGATKO
CAGE:53063
=== Contractor Identification ===
Company Name:ATLAS POWDER CO
Address:15301 DALLAS PARKWAY SUITE 1200
Box:City:DALLAS
State:TX
ZIP:75248
Country:US
Phone:717-386-4121
CAGE:53063
============= Composition/Information on Ingredients =============
Ingred Name:AMMONIUM (I) NITRATE (1:1); (AMMONIUM NITRATE)
CAS:6484-52-2
RTECS #:BR9050000
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:SUPDAT: SAWDUST. DO NOT STORE NEAR SOURCES OF HIGH HEAT
SUCH AS RADIATORS, STEAMPIPES OR ELECTRICAL WIRING.
RTECS #:9999999ZZ
Ingred Name:OTHER PREC: SHOULD BE KEPT AT LEAST 36 IN FROM EAVES & FROM
SUPPORT BEAMS & RAFTERS OVERHEAD. OPEN FLAMES, SPKS (ING 4)
RTECS #:9999999ZZ
Ingred Name:ING 3: & OTHER SOURCES OF HEAT SHOULD BE KEPT 50 FT AWAY
FROM STORAGE AREAS OF BAGS. SMKNG W/IN 50 FT OF STORAGE (ING 5)
RTECS #:9999999ZZ
Ingred Name:ING 4: AREAS MUST BE PROHIBITED. EMPTIED BAGS SHOULD BE
DISPOSED OF PROMPTLY & PROPERLY, I/A/W APPROP SOLID/HAZ (ING 6)
RTECS #:9999999ZZ
Ingred Name:ING 5: WASTE DISP REGS. DURING REPAIR & MAINT OF CONTAMD
EQUIP AVOID HEATING UNDER CONFINEMENT, ESP IF MATL IS (ING 7)
RTECS #:9999999ZZ
Ingred Name:ING 6: CONTAMD W/ORGANIC MATLS/HEAVY METALS SUCH AS COPPER
OR ZINC.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NO DATA WHICH INDICATES A HEALTH
HAZARD. HOWEVER, CONTACT WITH EYES CAN CAUSE PAIN AND IRRITATION,
IF PROLONGED.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INGEST: CALL MD IMMEDIATELY . EYES: IMMEDIATELY FLUSH
W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM
MD . INHAL: WILL EMIT OXIDES OF NITROGEN IF THERMAL DECOMPOSITION
OC CURS. DO NOT BREATHE THESE FUMES. IMMEDIATELY SEEK MEDICAL
ATTENTION. SKIN: WASH WITH WATER. IF BURNED, TREAT ACCORDINGLY.
===================== Fire Fighting Measures =====================
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:OXIDIZER; CAN EXPLODE IF BURNED IN
CONFINEMENT.
================== Accidental Release Measures ==================
Spill Release Procedures:DRY SPILLS, IF FREE OF ORG/COMBUST MATTER MAY
BE SAFELY SCOOPED INTO CNTNRS FOR IMMED USE/DISP. DO NOT
REBAG/STORE SPILLED MATL. IF MATL IS DAMP, IT SHOULD BE REMOVED &
USED IMMED. IF SPILL ENTERS SEW ER/WATERWAY, NOTIFY ENVIRON
AUTH/APPROPAGENCIES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:PROTECT CNTNRS AGAINST PHYSICAL DMG.
STORE IN WELL-VENT BLDGS, PREF OF NONCOMBUST CONSTRUCTION & PREF
EQUIPPED W/AUTOMATIC SPRINKLER PROT. (SUPDAT)
Other Precautions:BAGS OF AMMONIUM NITRATE SHOULD BE STORED NOT LESS
THAN 30 IN AWAY FROM WALLS OF STORAGE BLDG. BAGS SHOULD BE STACKED
& MADE ACCESSIBLE W/PROPER VENT PROVIDED. STACKS SHOULD NOT BE MORE
THAN 8-FT-WIDE & 7-FT-HIGH. WHERE APPLIC, BAGS (ING 3)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WEAR A NIOSH/MSHA APPROVED DUST MASK.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:PROTECT EYES AND SKIN FROM PROLONGED EXPOSURE.
Supplemental Safety and Health
HNDLG/STOR PREC: FLOOR DRAINS & RECESSES SHOULD BE PLUGGED/ELIM TO PVNT
ENTRAPMENT OF FLOW OF MOLTEN NITRATE DURING FIRE. SEPARATE, TO
AVOID MIXING, FROM ALL ORG MATLS/OTHER CONTAMINATING SUBSTANCES S
UCH AS FLAMM LIQS, ACIDS, CORR LIQS, ORG CHEMS, CHLORATES, SULFUR &
FINELY DIVIDED METALS/CHARCOAL, COKE & (ING 2)
================== Physical/Chemical Properties ==================
Melt/Freeze Pt:M.P/F.P Text:311F,155C
Spec Gravity:1.725
Solubility in Water:100%
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:OPEN FLAMES, SPARKS AND OTHER SOURCES OF
IGNITION.
Hazardous Decomposition Products:WILL EMIT OXIDES OF NITROGEN IF
THERMAL DECOMPOSITION OCCURS. DO NOT BREATHE THESE FUMES.
==================== Disposal Considerations ====================
Waste Disposal Methods:AMMONIUM NITRATE MUST BE CONSIDERED HAZARDOUS
WASTE PER 40 CFR 261. ALL FEDERAL, STATE & LOCAL HAZARDOUS WASTE
DISPOSAL REGS MUST BE COMPLIED WITH. IF MAJOR SPILL OCCURS, CONTACT
THE NRC (800-424-8802 ) & APPROP STATE ENVIRONMENTAL AUTHORITIES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.